Skip to main content

Main menu

  • Home
  • About
    • Clinical Chemistry
    • Editorial Board
    • Most Read
    • Most Cited
    • Alerts
    • CE Credits
  • Articles
    • Current Issue
    • Early Release
    • Future Table of Contents
    • Archive
    • Browse by Subject
  • Info for
    • Authors
    • Reviewers
    • Subscribers
    • Advertisers
    • Permissions & Reprints
  • Resources
    • AACC Learning Lab
    • Clinical Chemistry Trainee Council
    • Clinical Case Studies
    • Clinical Chemistry Guide to Scientific Writing
    • Clinical Chemistry Guide to Manuscript Review
    • Journal Club
    • Podcasts
    • Q&A
    • Translated Content
  • Abstracts
  • Submit
  • Contact
  • Other Publications
    • The Journal of Applied Laboratory Medicine

User menu

  • Subscribe
  • My alerts
  • Log in

Search

  • Advanced search
Clinical Chemistry
  • Other Publications
    • The Journal of Applied Laboratory Medicine
  • Subscribe
  • My alerts
  • Log in
Clinical Chemistry

Advanced Search

  • Home
  • About
    • Clinical Chemistry
    • Editorial Board
    • Most Read
    • Most Cited
    • Alerts
    • CE Credits
  • Articles
    • Current Issue
    • Early Release
    • Future Table of Contents
    • Archive
    • Browse by Subject
  • Info for
    • Authors
    • Reviewers
    • Subscribers
    • Advertisers
    • Permissions & Reprints
  • Resources
    • AACC Learning Lab
    • Clinical Chemistry Trainee Council
    • Clinical Case Studies
    • Clinical Chemistry Guide to Scientific Writing
    • Clinical Chemistry Guide to Manuscript Review
    • Journal Club
    • Podcasts
    • Q&A
    • Translated Content
  • Abstracts
  • Submit
  • Contact
Research ArticleGeneral Clinical Chemistry

Toward Standardization of Insulin Immunoassays

W. Greg Miller, Linda M. Thienpont, Katleen Van Uytfanghe, Penelope M. Clark, Patrik Lindstedt, Göran Nilsson, Michael W. Steffes
DOI: 10.1373/clinchem.2008.118380 Published April 2009
W. Greg Miller
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Linda M. Thienpont
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Katleen Van Uytfanghe
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Penelope M. Clark
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Patrik Lindstedt
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Göran Nilsson
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael W. Steffes
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Background: Measurement of circulating insulin may improve the classification and management of diabetes mellitus and assist in treating people with insulin resistance.

Methods: A work group convened by the American Diabetes Association evaluated results for a panel of 39 single donor sera measured by 10 commercial insulin methods from 9 manufacturers against an isotope dilution–liquid chromatography/tandem mass spectrometry (IDMS) measurement procedure calibrated using purified recombinant insulin. We used a candidate primary (pure substance) reference material, pooled serum, and single donor sera to evaluate approaches to achieve improved agreement of results between the routine and reference measurement procedures.

Results: Four of 10 methods had ≥95% of individual serum results within 32% of the IDMS concentrations. However, the bias vs IDMS was more than 15.5% for 7 of 10 methods in 36%–100% of individual samples. A purified recombinant insulin preparation used as a common calibrator did not improve harmonization of results among routine methods but was not used as instructed by all participants. Calibration using serum pools achieved bias <15.5% for nearly all results in the concentration range covered by the pools (>60 pmol/L). Calibration using a panel of individual sera was the most effective to improve harmonization of results over the full measuring range.

Conclusions: Agreement among methods can be improved by establishing traceability to the IDMS procedure using a panel of native sera. Pooled sera may be useful as trueness control materials. The usefulness of the pure insulin primary reference material [candidate reference material for insulin (cRMI)] requires clarification of protocols used by manufacturers.

  • © 2009 The American Association for Clinical Chemistry
View Full Text
PreviousNext
Back to top

In this issue

Clinical Chemistry: 55 (5)
Vol. 55, Issue 5
May 2009
  • Table of Contents
  • Index by author
  • Table of Contents (PDF)
  • Cover (PDF)
  • Advertising (PDF)
  • Ed Board (PDF)
Print
Share
Toward Standardization of Insulin Immunoassays
W. Greg Miller, Linda M. Thienpont, Katleen Van Uytfanghe, Penelope M. Clark, Patrik Lindstedt, Göran Nilsson, Michael W. Steffes
Clinical Chemistry May 2009, 55 (5) 1011-1018; DOI: 10.1373/clinchem.2008.118380
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
Article Alerts
Sign In to Email Alerts with your Email Address
Citation Tools
Toward Standardization of Insulin Immunoassays
W. Greg Miller, Linda M. Thienpont, Katleen Van Uytfanghe, Penelope M. Clark, Patrik Lindstedt, Göran Nilsson, Michael W. Steffes
Clinical Chemistry May 2009, 55 (5) 1011-1018; DOI: 10.1373/clinchem.2008.118380

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Materials and Methods
    • Results
    • Discussion
    • Conclusions
    • Acknowledgments
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

Cited By...

More in this TOC Section

  • Methylation Status and Neurodegenerative Markers in Parkinson Disease
  • A New Principle for Measurement of Cobalamin and Corrinoids, Used for Studies of Cobalamin Analogs on Serum Haptocorrin
Show more General Clinical Chemistry